No. 5-2, Jialu Rd., Douliu City, Yunlin County 640,Taiwan
No. 15, Ln. 51, Qingping St., Nanzi Dist, Kaohsiung City 811,Taiwan
By reason of air pollution, salt damage, biogas, exhaust and drainage equipment, and little chance of rain in Taiwan environment, the dust, biogas, oil pollution, birds’ droppings, etc., easily adhere to the solar modules. If the power plant adopts traditional inverters, due to the string effect, the low current of a single module will affect the power generation of the other 20-21 modules in the same string, and even lead to hot spots because of the increase in resistance in modules. In order to retard and prevent the above situations, it is essential to have regular maintenance and management executed by a professional O&M team.
Birds’ Droppings
Dust
Cracks of Module
1. Bracket inspection | 2. Photoelectric module testing | 3. Inverter testing |
4. DC box testing | 5. AC panel testing | 6. Meteorological system testing |
7. Monitoring system testing | 8. Trunking inspection | 9. Solar module cleaning (tap water, one-time construction method) |
10. Failure handling and abnormality exclusion | 11. Safety facilities inspection | 12. Wholesale electricity meters |
13. Islanding effect testing |
Equipment | Elements |
---|---|
1. High and low voltage electrical equipment closing down for testing and maintenance | |
DS | Contact resistance, insulation resistance, DC withstand voltage, equipment cleaning and maintenance |
VCB | Contact resistance, insulation resistance, DC withstand voltage, three-phase action time, equipment cleaning and maintenance |
LBS | Contact resistance, insulation resistance, DC withstand voltage, equipment cleaning and maintenance |
PF | Insulation resistance, DC withstand voltage, equipment cleaning and maintenance |
CT | Insulation resistance, DC withstand voltage, equipment cleaning and maintenance |
PT | Insulation resistance, DC withstand voltage, equipment cleaning and maintenance |
HV-SV | Capacitance quality verification, insulation resistance, DC withstand voltage, equipment cleaning and maintenance |
TR | Insulation resistance, DC withstand voltage, Oil type are added with oil withstand voltage and acid value, equipment cleaning and maintenance |
Cable | Insulation medium absorption, DC withstand voltage, equipment cleaning and maintenance |
LA | Insulation resistance, DC withstand voltage, equipment cleaning and maintenance |
ACB | Contact resistance, insulation resistance, equipment cleaning and maintenance |
NFB | Insulation resistance, equipment cleaning and maintenance |
LV SC | Capacitance quality verification, insulation resistance, equipment cleaning and maintenance |
IED | Operating characteristic, DC tripping, equipment cleaning and maintenance |
Earth | Earthing resistance judgement |
2. High and low voltage electrical equipment infrared heat influence for testing and analysis | |
1 | Module broken cable detection |
2 | Grounding equipment failure detection |
The Company
Solutions
Taiwan (Headquarter)
7F, No.190, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231,Taiwan
sales@billionwatts.com.tw
Australia
Australia Square, Level 42, 264 George Street, Sydney NSW 2000.
sales@billionwatts.com.tw
About Billion Watts
Service items
Taiwan (Headquarter)
7F, No.190, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231,Taiwan
sales@billionwatts.com.tw
Australia
Australia Square, Level 42, 264 George Street, Sydney NSW 2000.
sales@billionwatts.com.tw
Contact Us
Taiwan (Headquarter)
7F, No.190, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231,Taiwan
sales@billionwatts.com.tw
Australia
Australia Square, Level 42, 264 George Street, Sydney NSW 2000.
sales@billionwatts.com.tw