Giga
PV Inverter
BNI 50-60KTL3-X LV
5-year warranty, extendable to 20 years
The maximum conversion efficiency is 98.8%, the efficiency of European standard is 98.4%, the maximum DC input voltage is 1100V, suitable for bifacial solar modules, 3-way MPPT, intelligent air cooling, AC & DC type II SPD, OLED display, touch buttons, and flexible monitoring methods.
Product Features
- Maximum efficiency 98.8%, European efficiency 98.4%
- Maximum DC input voltage 1100V
- String current 12.5A, suitable for bifacial solar modules
- AC & DC type II SPD, one-click diagnosis
- OLED display screen and touch buttons
- Flexible monitoring method-USB/RS485
Model
| BNI 50KTL3-X LV | BNI 60KTL3-X LV |
|---|
Product Specifications
| Model | BNI 50KTL3-X LV | BNI 60KTL3-X LV | |
|---|---|---|---|
| Input data (DC) | Max. recommended PV power | 65000W | 78000W |
| Max.DC voltage | 1100V | 1100V | |
| Start voltage | 250V | 250V | |
| Rated voltage | 600V | 600V | |
| MPP voltage range | 200V ~ 1000V | 200V ~ 1000V | |
| No. of MPP trackers | 3 | 3 | |
| Max. No. of PV strings per MPP tracker | 4 / 4 / 3 | 4 / 4 / 3 | |
| Max. input current per MPP tracker | 50A / 50A / 37.5A | 50A / 50A / 37.5A | |
| Max. short-circuit current per MPP tracker | 55A / 55A / 55A | 55A / 55A / 55A | |
| Output data (AC) | Rated AC output power | 50000W | 60000W |
| Max. AC apparent power | 55500VA | 66600VA | |
| Rated AC voltage | 380V | 380V | |
| AC grid frequency | 60Hz | 60Hz | |
| Max. output current | 84.4A | 96.6A | |
| AC grid connection type | 3W / N / PE | 3W / N / PE | |
| Efficiency | Max. efficiency | 98.8% | 98.8% |
| European efficiency | 98.4% | 98.4% | |
| General Data | Dimensions (W / H / D) | 680 x 508 x 281 mm | 680 x 508 x 281 mm |
| Weight | 52kg | 52kg | |
| Nighttime power consumption | <1W | <1W | |
| Topology | Transformerless | Transformerless | |
| Cooling | Smart air cooling | Smart air cooling | |
| Protection degree | IP65 | IP65 | |
| DC connection | MC4 | MC4 | |
| Display and Communication | Display | OLED | OLED |
| RS485 / USB | Yes | Yes | |
| Wi-Fi | Optional | Optional | |
| Warranty:5 years / 10 years | Yes / Optional | Yes / Optional | |
| Standards Compliant | IEC 60529, IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-3, EN 61000-6,CNS 15382, CNS 15426-1, CNS 15426-2, CNS 14674-2, CNS 14674-4, VPC | IEC 60529, IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-3, EN 61000-6,CNS 15382, CNS 15426-1, CNS 15426-2, CNS 14674-2, CNS 14674-4, VPC |
| Model | BNI 50KTL3-X LV | BNI 60KTL3-X LV | |
|---|---|---|---|
| Protection Devices | DC reverse polarity protection | Yes | Yes |
| DC switch | Yes | Yes | |
| DC surge protection | Type II | Type II | |
| Insulation resistance monitoring | Yes | Yes | |
| AC surge protection | Type II | Type II | |
| AC short-circuit protection | Yes | Yes | |
| Ground fault monitoring | Yes | Yes | |
| Grid monitoring | Yes | Yes | |
| Anti-islanding protection | Yes | Yes | |
| Residual-current monitoring unit | Yes | Yes |
* Our company is not responsible for any omissions, misstatements or non-factual statements (whether express or implied) in this product specification, please contact us for further information.