Giga
PV Inverter
BNI 125-150KTL3-X MV
5-year warranty, extendable to 20 years
The maximum conversion efficiency is 98.8%, the efficiency of European standard is 98.5%, the maximum DC input voltage is 1100V, suitable for bifacial solar modules, 10-way MPPT, intelligent air cooling, AC & DC type II SPD, LED display, and flexible monitoring methods.
Product Features
- 10-channel MPPT design to adapt to complex application scenarios
- Support string monitoring and real-time detection of system malfunctions
- AC & DC type II SPD
- IP66 protection level
Model
| BNI 125KTL3-X MV | BNI 150KTL3-X MV |
|---|
Product Specifications
| Model | BNI 125KTL3-X MV | BNI 150KTL3-X MV | |
|---|---|---|---|
| Input data (DC) | Max.DC voltage | 1100V | 1100V |
| Start voltage | 195V | 195V | |
| Rated voltage | 720V | 720V | |
| MPP voltage range | 180V ~ 1000V | 180V ~ 1000V | |
| No. of MPP trackers / Max. No. of PV strings per MPP tracker | 10 / 2 | 10 / 2 | |
| Max. input current per MPP tracker | 32A | 32A | |
| Max. short-circuit current per MPP tracker | 40A | 40A | |
| Output data (AC) | Rated AC output power | 125KW | 150KW |
| Max. AC apparent power | 137.5KVA | 165KVA | |
| Max. output current | 165.4A | 198.5A | |
| Rated AC voltage | 480V | 480V | |
| AC grid frequency | 60Hz | 60Hz | |
| Efficiency | Max. efficiency | 99% | 99% |
| European efficiency | 98.5% | 98.5% | |
| General Data | Dimensions (W / H / D) | 970 x 640 x 345 mm | 970 x 640 x 345 mm |
| Weight | 84kg | 84kg | |
| Nighttime power consumption | <1W | <1W | |
| Topology | Transformerless | Transformerless | |
| Cooling | Smart air cooling | Smart air cooling | |
| Protection degree | IP66 | IP66 | |
| DC connection | MC4 | MC4 | |
| Display and Communication | Display | LED | LED |
| RS485 / USB / Wi-Fi | Yes / Yes / Optional | Yes / Yes / Optional | |
| Warranty:5 years / 10 years | Yes / Optional | Yes / Optional | |
| Standards Compliant | IEC 60529, IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-3, EN 61000-6,NB/T 32004-2018, CGC/GF 035-2013, GB/T 19964-2012, VPC | IEC 60529, IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-3, EN 61000-6,NB/T 32004-2018, CGC/GF 035-2013, GB/T 19964-2012, VPC |
| Model | BNI 125KTL3-X MV | BNI 150KTL3-X MV | |
|---|---|---|---|
| Protection Devices | DC reverse polarity protection | Yes | Yes |
| DC switch | Yes | Yes | |
| DC surge protection | Yes | Yes | |
| Insulation resistance monitoring | Yes | Yes | |
| AC surge protection | Yes | Yes | |
| AC short-circuit protection | Yes | Yes | |
| Ground fault monitoring | Yes | Yes | |
| Grid monitoring | Yes | Yes | |
| Anti-islanding protection | Yes | Yes | |
| Residual-current monitoring unit | Yes | Yes | |
| String detection | Yes | Yes | |
| Arc Fault Protection | Optional | Optional | |
| PID prevention | Optional | Optional |
* Our company is not responsible for any omissions, misstatements or non-factual statements (whether express or implied) in this product specification, please contact us for further information.